DE eng

Search in the Catalogues and Directories

Hits 1 – 12 of 12

1
Disruptive Dizziness among Post-9/11 Veterans with Deployment-Related Traumatic Brain Injury
In: ETSU Faculty Works (2021)
BASE
Show details
2
The Development of the Benign Paroxysmal Positional Vertigo Symptom Impact Questionnaire (BSIQ)
In: ETSU Faculty Works (2019)
BASE
Show details
3
The Development of the Benign Paroxysmal Positional Vertigo Symptom Impact Questionnaire (BSIQ)
In: ETSU Faculty Works (2019)
BASE
Show details
4
Vestibular Consequences of Mild Traumatic Brain Injury and Blast Exposure: A Review
In: ETSU Faculty Works (2017)
BASE
Show details
5
Reliability and Validity of Bertec Computerized Dynamic Posturography
In: ETSU Faculty Works (2017)
BASE
Show details
6
Vestibular Consequences of mTBI and Blast Exposure
In: ETSU Faculty Works (2016)
BASE
Show details
7
Reliability and Normative Data for the Dynamic Visual Acuity Test for Vestibular Screening
In: ETSU Faculty Works (2016)
Abstract: Hypothesis: The purpose of this study was to determine reliability of computerized dynamic visual acuity (DVA) testing and to determine reference values for younger and older adults. Background: A primary function of the vestibular system is to maintain gaze stability during head motion. The DVA test quantifies gaze stabilization with the head moving versus stationary. Commercially available computerized systems allow clinicians to incorporate DVA into their assessment; however, information regarding reliability and normative values of these systems is sparse. Methods: Forty-six healthy adults, grouped by age, with normal vestibular function were recruited. Each participant completed computerized DVA testing including static visual acuity, minimum perception time, and DVA using the NeuroCom inVision System. Testing was performed by two examiners in the same session and then repeated at a follow-up session 3 to 14 days later. Intraclass correlation coefficients (ICCs) were used to determine inter-rater and test–retest reliability. Results: ICCs for inter-rater reliability ranged from 0.323 to 0.937 and from 0.434 to 0.909 for horizontal and vertical head movements, respectively. ICCs for test–retest reliability ranged from 0.154 to 0.856 and from 0.377 to 0.9062 for horizontal and vertical head movements, respectively. Overall, raw scores (left/right DVA and up/down DVA) were more reliable than DVA loss scores. Conclusion: Reliability of a commercially available DVA system has poor-to-fair reliability for DVA loss scores. The use of a convergence paradigm and not incorporating the forced choice paradigm may contribute to poor reliability.
Keyword: Audiology and Speech-Language Pathology; dva; dynamic visual acuity; Physical Therapy; Rehabilitation and Therapy; reliability; vestibular; vestibular screening
URL: https://dc.etsu.edu/etsu-works/548
https://doi.org/10.1097/MAO.0000000000001014
BASE
Hide details
8
Video Head Impulse Testing (vHIT) and the Assessment of Horizontal Semicircular Canal Function
In: ETSU Faculty Works (2015)
BASE
Show details
9
Vestibular Consequences of mTBI and Blast Exposure
In: ETSU Faculty Works (2015)
BASE
Show details
10
Effects of Age on Vestibular and Balance Systems
In: ETSU Faculty Works (2015)
BASE
Show details
11
A Benign Paroxysmal Positional Vertigo Specialty Clinic: A Model for Va Health Care
In: ETSU Faculty Works (2013)
BASE
Show details
12
Interdisciplinary Approach to Dizziness: Roles of Audiology and Physical Therapy
In: ETSU Faculty Works (2013)
BASE
Show details

Catalogues
0
0
0
0
0
0
0
Bibliographies
0
0
0
0
0
0
0
0
0
Linked Open Data catalogues
0
Online resources
0
0
0
0
Open access documents
12
0
0
0
0
© 2013 - 2024 Lin|gu|is|tik | Imprint | Privacy Policy | Datenschutzeinstellungen ändern